Measurement / calibration of the angle between the signal generated between the UV phase towards the relative Hall Sensor U, between the VW phase towards the relative Hall V sensor and between the WU phase towards the relative Hall W Sensor. In this measure accuracy is guaranteed 1st (or better) for speeds up to 1000RPM. Test applicable to Brushless Generators equipped with Hall Sensors.