No Load Test with check of the relation between the Turns Primary/Secundary and Secondary Phase
Functional Tests
Spark Test
Bonding of windings with costant voltage or constant current, using 2 or 3 generators in parallel (Versions 320/ACS-2 and 320/ACS-3)
Load Test - Version for Generator/Alternator
No Load Test with measurement of the voltages U-V, V-W and W-U at 1000RPM (or other speed t.b.d.) - Test for Generators/Alternators
FFT Analysis of the 3 voltages generated, with automatic calculation of the THD - Test for Generators/Alternators
Load Test on the Transformer
Functional Test with Load applied
DLT (Dynamic Load Test) with acquisition of the Torque – RPM measurement without mechanical brakes on DC Motors
Absorption Test at Nominal Voltage (Functional Test)
Start-up Test at Reduced Voltage
DLT (Dynamic Load Test) with acquisition of the Torque – RPM measurement without mechanical brakes on AC Motors (and Brushless)
DET Dynamic Electrical Test
TR Measurement of the Rotor Blocked Current and the Start-up Time (without any external mechanical device) for AC Motors
Measurement of the Rotation Direction through Magnetic Sensor
Measurement of the Rotation Speed RPM without sensors on DC Motors
Measurement of the Rotation Speed RPM through an optical or a vibration sensor
Tests at higher frequency
No Load Test with check of the relation between the Turns Primary/Secundary and Secondary Phase
No Load Test with check of the relation between the Turns Primary/Secundary and Secondary Phase
This test is applied in the testing of transformers. The voltage in the primary is measured with respect to the secondary, measuring both the ratio between the voltages and the phases, leaving the secondary at no load. Generally the voltage is in phase (0 °) or out of phase (180 °).
Request for information
Request for information about "No Load Test with check of the relation between the Turns Primary/Secundary and Secondary Phase"
Request (required field)
You have to insert a request
Name (required field)
You have to insert your name
Company name
You have to insert your company name
E-mail (required field)
You have to insert your e-mail address
You have to insert a valid e-mail address
Telephone
You have to insert your telephone number
I declare to have read the
Privacy
yes, I have read
Mandatory
Send
×
Share this page
Share for e-mail "No Load Test with check of the relation between the Turns Primary/Secundary and Secondary Phase"
Sender name(required field)
You have to insert sender name
Sender e-mail(required field)
You have to insert sender e-mail
You have to insert a valid sender e-mail address
Recipient name(required field)
You have to insert recipient name
Recipient e-mail address(required field)
You have to insert recipient e-mail address
You have to insert a valid recipent e-mail address
Message(required field)
You have to insert a message
Send
×
Functional Tests
Code:
ATT/PV
Product that perform No Load Test with check of the relation between the Turns Primary/Secundary and Secondary Phase
Standard
ATT320/W
Automatic Testing System for Transformers
Previous
Tests at higher frequency
Back to
Functional Tests
Next
Spark Test